Low temperature
space is classified by on the service conditions. The construction
and design of the cold storage facility depends on the needs of each
classification.
•Coolers - Above 0ºC (32ºF)
•Coolers - Below freezing to minus 2ºC (28ºF)
•Freezers - Minus 23ºC (-9ºF) to minus 33ºC (-29ºF) - Constant
temperature
•Sharp Freezers - Cycle from room temperature down to minus 40ºC
(-40ºF)
•Cryogenic Service - Below minus 100ºC |
Cold Storage
According
to the US Department of Agriculture, there was over 3.04 billion gross cubic
feet of general refrigerated or cold storage capacity in 2001. These
facilities are essential for the safe handling and storage of food products
and other goods. Without a storage area that provides a consistent
environment that can sustain its integrity, many products would not be
readily available to consumers.
Expanded polystyrene insulation board is ideal for use in
walls and roofing systems in the construction of cold storage space. These
facilities store food, flowers, and other temperature sensitive commodities.
The temperatures range from normal room temperature 20ºC (68ºF) to cryogenic
temperatures -100ºC (-148ºF). As the surface (of what?) temperature
decreases, the quality of construction and sustainability required becomes
more critical.
The
performance properties of EPS, including constant thermal resistance,
dimensional stability, chemical inertness and sustainability, make it well
suited for use as insulation. Additionally, its closed-cell structure
provides minimal water absorption and low vapor
permeance; an important design consideration for damp environments.
Cold storage insulation is normally applied in 2 layers with
joints staggered between layers and boards tightly butted. The EPS boards
must be firmly and permanently bonded to the wall, ceiling, and roof using
adhesives. The first layer of floor insulation is bonded to sub-slab while
the second layer is installed dry. Thicker coatings of heavy bodied
adhesives may be used to provide some straightening or bridging on an
irregular wall surface. Adhesives are applied to provide 100% contact and to
fill any voids. Spot or strip applications of adhesives are used only where a
vapor or air barrier is installed.
All components of construction must work together to achieve a
system that will enclose space and hold it at the desired temperature for
extended periods of time without any deterioration. For instance, it is
recommended that any lumber incorporated into cold storage construction be
pressure treated with a wood preservative.
Ensuring
a low temperature, the space must be properly enclosed and equally important,
the removal of heat generated from refrigeration equipment and other
machinery. There are several methods that can be employed to eliminate heat
sources from the space to reduce maintenance problems.
To achieve maximum insulation efficiency and long-term
performance, mechanical equipment may be adapted for the cold temperatures.
Refrigeration units can be reduced in size to decrease the amount of heat
generated. And, they should have an automatic defrosting cycle. Other items
such as pumps, fans and lights should also operate properly. The thickness
and type of insulation in the construction deters the movement of outside
weather and normal self-generating building heat.
The use of doors plays a large role in the ability to sustain
the appropriate temperature. The frequency of door opening and closing is of
greater concern than the size of the door. Operational guidelines should be
established to quickly expedite the loading and unloading of product in the
cold rooms. Forklift truck operation and other mechanical systems allow quick
opening and closing doors with mechanical or remote operators. The
investment on doors can result in energy savings by decreasing the amount of
heat transfer. Holding areas with a regular door outside of the cold room can
also help reduce the flow of warm air into a cold area.
Contractors must be aware of unsealed openings around
electrical conduit and equipment hangars, structural cracks and poorly
constructed joints at the wall - ceiling line, construction joints, etc.
Warm air can infiltrate the storage area through these imperfections
compromising the environment. When warm, moist air enters a freezer room it
can cause a rapid build up of ice, which can force movement of the structure.
Frequently, goods entering the facility have a higher
temperature than that of the storage area. Design provisions must be
incorporated in the refrigeration unit to remove the newly introduced heat.
In the same respect, any modifications to the design or
operation of the building or special care in workmanship which lowers heat
gain within the cold room will reduce the load on the refrigeration equipment
which can effect noticeable energy savings. It is critical that the necessary
prevention of heat gain can be assured at the design stage to minimize the
refrigeration equipment needed.
The construction must be tight so that is no air movement
through the structure from the outside to the inside of the room. The
location of air seals and vapor barriers can be cold storage rooms. The
movement of water vapor must be restricted by the use of vapor barriers or by
the vapor barrier characteristics of EPS rigid foam insulation. The
placement of air seals and vapor barriers in the construction is imperative
to reduce the possibility of leakage.
Expanded
polystyrene insulation meets extensive model building code requirements.
More than 48 EPS manufacturers with hundreds of locations in the U.S. and
Canada maintain numerous listings at Factory Mutual (FM), Underwriters
Laboratory (UL), Underwriters Laboratory of Canada (ULC) and other testing
facilities.
|